T-box Zone |
Intelligent controller with touch screen, built-in room thermostat and programable week calendar, one controller can control up to 31 units, multi-zone control - can create up to 31 zones and control each unit independently, can be connected to BMS |
|
T-box Zone |
|
Intelligent controller with touch screen, built-in room thermostat and programable week calendar, one controller can control up to 31 units, multi-zone control - can create up to 31 zones and control each unit independently, can be connected to BMS |
|
Cube OV-COND-FA2 |
28 kW capacity reversible condensing unit module for Cube OV unit with DX heat exchanger |
|
Cube OV-COND-FA2 |
|
28 kW capacity reversible condensing unit module for Cube OV unit with DX heat exchanger |
|
Cube OV-COND-FA5 |
56 kW capacity reversible condensing unit module for Cube OV unit with DX heat exchanger |
|
Cube OV-COND-FA5 |
|
56 kW capacity reversible condensing unit module for Cube OV unit with DX heat exchanger |
|
Cube OV-Gm34 |
Gas fired heater module for Cube OV unit (for installation outdoors under the main roof module), 8.13 - 33.56 kW modulating heat output, efficiency while working on min. - max. power 106.97 - 96.30%, minimum air flow 3500 m³/h, max. gas (G20) consumption while working on min. - max. power 0.80 - 3.69 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 8.7 - 9.1%, gas connection 3/4" |
|
Cube OV-Gm34 |
|
Gas fired heater module for Cube OV unit (for installation outdoors under the main roof module), 8.13 - 33.56 kW modulating heat output, efficiency while working on min. - max. power 106.97 - 96.30%, minimum air flow 3500 m³/h, max. gas (G20) consumption while working on min. - max. power 0.80 - 3.69 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 8.7 - 9.1%, gas connection 3/4" |
|
Cube OV-Gm45 |
Gas fired heater module for Cube OV unit (for installation outdoors under the main roof module), 8.97 - 40.45 kW modulating heat output, efficiency while working on min. - max. power 105.50 - 96.30%, minimum air flow 4200 m³/h, max. gas (G20) consumption while working on min. - max. power 0.90 - 4.44 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 8.7 - 9.1%, gas connection 3/4" |
|
Cube OV-Gm45 |
|
Gas fired heater module for Cube OV unit (for installation outdoors under the main roof module), 8.97 - 40.45 kW modulating heat output, efficiency while working on min. - max. power 105.50 - 96.30%, minimum air flow 4200 m³/h, max. gas (G20) consumption while working on min. - max. power 0.90 - 4.44 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 8.7 - 9.1%, gas connection 3/4" |
|
Cube OV-Gm65 |
Gas fired heater module for Cube OV unit (for installation outdoors under the main roof module), 13.40 - 62.93 kW modulating heat output, efficiency while working on min. - max. power 108.06 - 96.82%, minimum air flow 6500 m³/h, max. gas (G20) consumption while working on min. - max. power 1.31 - 6.88 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 8.7 - 9.1%, gas connection 3/4" |
|
Cube OV-Gm65 |
|
Gas fired heater module for Cube OV unit (for installation outdoors under the main roof module), 13.40 - 62.93 kW modulating heat output, efficiency while working on min. - max. power 108.06 - 96.82%, minimum air flow 6500 m³/h, max. gas (G20) consumption while working on min. - max. power 1.31 - 6.88 m³/h, CO₂ content of the exhaust gas while working on min. - max. power 8.7 - 9.1%, gas connection 3/4" |
|
Cube OV-RTM |
Roof transition module for Cube OV unit, the main roof module or gas heater module is placed on top of it |
|
Cube OV-RTM |
|
Roof transition module for Cube OV unit, the main roof module or gas heater module is placed on top of it |
|
Cube OV/ADM |
Air distribution module for Cube OV unit, for mounting under the roof transition module, contaminated room air is extracted through the grilles on the side of this module, a hot water heat exchanger can be installed inside this module |
|
Cube OV/ADM |
|
Air distribution module for Cube OV unit, for mounting under the roof transition module, contaminated room air is extracted through the grilles on the side of this module, a hot water heat exchanger can be installed inside this module |
|
Cube OV/W2 |
Water heater for Cube OV unit, mounted inside air distribution module, two row heat exchanger, 62.4 kW heating capacity at 70/50°C water and -16°C air temperatures, 1" water connection |
|
Cube OV/W2 |
|
Water heater for Cube OV unit, mounted inside air distribution module, two row heat exchanger, 62.4 kW heating capacity at 70/50°C water and -16°C air temperatures, 1" water connection |
|
Cube OV/W3 |
Water heater for Cube OV unit, mounted inside air distribution module, three row heat exchanger, 68.7 kW heating capacity at 60/40°C water and -16°C air temperatures, 1" water connection |
|
Cube OV/W3 |
|
Water heater for Cube OV unit, mounted inside air distribution module, three row heat exchanger, 68.7 kW heating capacity at 60/40°C water and -16°C air temperatures, 1" water connection |
|
Cube OV/W4 |
Water heater for Cube OV unit, mounted inside air distribution module, four row heat exchanger, 56.0 kW heating capacity at 40/30°C water and -16°C air temperatures, 1¼" water connection |
|
Cube OV/W4 |
|
Water heater for Cube OV unit, mounted inside air distribution module, four row heat exchanger, 56.0 kW heating capacity at 40/30°C water and -16°C air temperatures, 1¼" water connection |
|
Cube OV/X2 |
Water cooler / heater module for Cube OV unit, two row heat exchanger, 24.6 kW cooling capacity at 6/12°C water and 30°C air temperatures, 62.4 kW heating capacity at 70/50°C water and -16°C air temperatures, 1" water connection, built-in condensate trap |
|
Cube OV/X2 |
|
Water cooler / heater module for Cube OV unit, two row heat exchanger, 24.6 kW cooling capacity at 6/12°C water and 30°C air temperatures, 62.4 kW heating capacity at 70/50°C water and -16°C air temperatures, 1" water connection, built-in condensate trap |
|
Cube OV/X3 |
Water cooler / heater module for Cube OV unit, three row heat exchanger, 35.9 kW cooling capacity at 6/12°C water and 30°C air temperatures, 68.7 kW heating capacity at 60/40°C water and -16°C air temperatures, 1" water connection, built-in condensate trap |
|
Cube OV/X3 |
|
Water cooler / heater module for Cube OV unit, three row heat exchanger, 35.9 kW cooling capacity at 6/12°C water and 30°C air temperatures, 68.7 kW heating capacity at 60/40°C water and -16°C air temperatures, 1" water connection, built-in condensate trap |
|
Cube OV/X4 |
Water cooler / heater module for Cube OV unit, four row heat exchanger, 48.7 kW cooling capacity at 6/12°C water and 30°C air temperatures, 56.0 kW heating capacity at 40/30°C water and -16°C air temperatures, 1¼" water connection, built-in condensate trap |
|
Cube OV/X4 |
|
Water cooler / heater module for Cube OV unit, four row heat exchanger, 48.7 kW cooling capacity at 6/12°C water and 30°C air temperatures, 56.0 kW heating capacity at 40/30°C water and -16°C air temperatures, 1¼" water connection, built-in condensate trap |
|
Cube OV/DX-FA2 |
DX (Direct eXpansion) heat exchanger module for Cube OV unit, dedicated for 28 kW capacity outdoor condensing unit, minimum air flow 4000 m³/h, recommended temperature range before the exchanger in cooling 18-13°C (DB - Dry Bulb) / 32-23°C (WB - Wet Bulb), recommended temperature range before the exchanger in heating 10-24°C, fluid connection diameter 1/2", gas nipple diameter 3/4", capacity 3.25 dm³, max. working pressure 42 bar, built-in condensate trap |
|
Cube OV/DX-FA2 |
|
DX (Direct eXpansion) heat exchanger module for Cube OV unit, dedicated for 28 kW capacity outdoor condensing unit, minimum air flow 4000 m³/h, recommended temperature range before the exchanger in cooling 18-13°C (DB - Dry Bulb) / 32-23°C (WB - Wet Bulb), recommended temperature range before the exchanger in heating 10-24°C, fluid connection diameter 1/2", gas nipple diameter 3/4", capacity 3.25 dm³, max. working pressure 42 bar, built-in condensate trap |
|
Cube OV/DX-FA5 |
DX (Direct eXpansion) heat exchanger module for Cube OV unit, dedicated for 56 kW capacity outdoor condensing unit, minimum air flow 4000 m³/h, recommended temperature range before the exchanger in cooling 18-13°C (DB - Dry Bulb) / 32-24°C (WB - Wet Bulb), recommended temperature range before the exchanger in heating 10-24°C, fluid connection diameter 5/8", gas nipple diameter 11/8", capacity 8.75 dm³, max. working pressure 42 bar, built-in condensate trap |
|
Cube OV/DX-FA5 |
|
DX (Direct eXpansion) heat exchanger module for Cube OV unit, dedicated for 56 kW capacity outdoor condensing unit, minimum air flow 4000 m³/h, recommended temperature range before the exchanger in cooling 18-13°C (DB - Dry Bulb) / 32-24°C (WB - Wet Bulb), recommended temperature range before the exchanger in heating 10-24°C, fluid connection diameter 5/8", gas nipple diameter 11/8", capacity 8.75 dm³, max. working pressure 42 bar, built-in condensate trap |
|
Cube OV/D |
Air supply module with swirl diffuser controlled by electric actuator for Cube OV unit |
|
Cube OV/D |
|
Air supply module with swirl diffuser controlled by electric actuator for Cube OV unit |
|
Cube OV/V |
Air supply module with 4 pcs. of ventilation ducts connections, for Cube OV unit |
|
Cube OV/V |
|
Air supply module with 4 pcs. of ventilation ducts connections, for Cube OV unit |
|
Cube OV/J |
Air supply module with 4 pcs. of long range nozzles, for Cube OV unit |
|
Cube OV/J |
|
Air supply module with 4 pcs. of long range nozzles, for Cube OV unit |