Electric heat pump, reversible, Air/Air, in the heating mode it takes heat from the Outdoor Air and transfers it to the Indoor Air, in cooling mode it takes heat from the Indoor Air and transfers it to the Outdoor Air, consists of outdoor and indoor unit, OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
Vai jūs interesē šis produkts? Sazinieties ar mums:

Andrejs Policans

LV, RU, EN
+371 209 26663

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
KITA AIR - reversible, Air/Air, in the heating mode it takes heat from the Outdoor Air and transfers it to the Indoor Air, in cooling mode it takes heat from the Indoor Air and transfers it to the Outdoor Air, consists of outdoor and indoor unit
KITA AIR OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR
OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR COLD OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR COLD
OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR PLUS OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR PLUS
OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for direct horizontal air blowing, air flow 5800-14000 m³/h, max. throw distance 25 m, max. electrical power consumption 0.835 kW, max. sound pressure level at a distance of 3 m from the unit 42 dB(A), dimensions 1253x765xH1090 mm, weight 100 kg
KITA AIR DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 39 kW (A7/A20), COP 4.45 (A7/A20), nominal cooling capacity 35 kW (A35/A27), EER 4.02 (A35/A27), max. electrical power consumption 14.2 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR COLD DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR COLD DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 40 kW (A7/A20), COP 4.36 (A7/A20), nominal cooling capacity 37 kW (A35/A27), EER 4.20 (A35/A27), max. electrical power consumption 16 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 1791x725xH1292 mm, weight 285 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR PLUS DUCTED OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
KITA AIR PLUS DUCTED
OUTDOOR UNIT DATA: nominal thermal capacity 47 kW (A7/A20), COP 4.20 (A7/A20), nominal cooling capacity 39 kW (A35/A27), EER 4.00 (A35/A27), max. electrical power consumption 18 kW, max. sound pressure level at a distance of 5 m from the unit 38 dB(A), operating temperature of outside air in heating mode -25/+28°C, operating temperature of outside air in cooling mode +5/+45°C, refrigerant type R32, max. distance to indoor unit 30 m, dimensions 2021x956xH1414 mm, weight 370 kg, INDOOR UNIT DATA: for air supply via ducts, nominal air flow (without filter / with filter) 11000/9300 m³/h at 150 Pa, max. electrical power consumption 1.3 kW, dimensions 1598x1011xH978 mm, weight 208 kg
Modelis: KITA AIR COLD
Vispārējie dati
Nominal heating output at 7°C outdoor and 20°C indoor air temperature
kW
40,0
Nominal heating output at -7°C outdoor and 20°C indoor air temperature
kW
35,0
COP - heating coefficient of performance at 7°C outdoor and 20°C indoor air temperature
4,36
COP - heating coefficient of performance at -7°C outdoor and 20°C indoor air temperature
3,10
Nominal cooling output at 35°C outdoor and 27°C indoor air temperature
kW
37,0
EER - cooling energy efficiency ratio at 35°C outdoor and 27°C indoor air temperature
4,20
Max. electrical power consumption
kW
16,835
Compressor system
Type
Inverter steam injection scroll
Refrigerant type
R32
Refrigerant GWP
675
Refrigerant quantity if distance between outdoor and indoor unit does not exceed 10 m
kg
7,4
Outdoor unit data
Max. electrical power consumption
kW
16
Ventilatora tips
Inverter BLDC (Brushless DC)
Nominal fan diameter
mm Ø
910
Max. fan rotation speed
rpm
640
Max. fan power consumption
kW
0,7
Max. fan current consumption
A
1,1
Maks. gaisa plūsma
m³/st.
17203
Max. acoustic pressure level at a distance of 5 m from the unit
dB(A)
38
Indoor unit data
Air delivery type
Direct horizontal air blow
Ventilatora tips
Inverter BLDC (Brushless DC)
Nominal fan diameter
mm Ø
800
Max. fan rotation speed
rpm
735
Max. electrical power consumption
kW
0,835
Max. electrical current consumption
A
1,4
Min. air flow
m³/st.
5800
Maks. gaisa plūsma
m³/st.
14000
Air throw distance
m
25
Max. acoustic pressure level at a distance of 3 m from the unit
dB(A)
42
Number of heat exchanger rows
3
Heat exchanger fin spacing
mm
1,7
Instalācijas dati
Power supply
V / Hz / Ph
400 / 50 / 3
Max. electrical power consumption
kW
16,835
Gas coolant connection diameter
Ø mm (")
22 (7/8)
Liquid coolant connection diameter
Ø mm (")
16 (5/8)
Max. coolant connection length between outdoor and indoor unit
m
30
Operating temperature range in heating mode
°C
-25 / +28
Operating temperature range in cooling mode
°C
+5 / +45
Outdoor unit dimensions
Platums
mm
1791
Dziļums
mm
725
Augstums
mm
1292
Svars
kg
285
Indoor unit dimensions
Platums
mm
1253
Dziļums
mm
765
Augstums
mm
1090
Svars
kg
100

Izmēri

Modelis: KITA AIR COLD
MODEL Heating Cooling
A 12°C / A 20°C A 7°C / A 20°C A 2°C / A 20°C A -7°C / A 20°C A -15°C / A 20°C A -20°C / A 20°C A 35°C / A 27°C
Qh COP Qh COP Qh COP Qh COP Qh COP Qh COP Qc EER
kW kW kW kW kW kW kW
KITA AIR 39,00 4,70 39,00 4,45 35,00 3,75 32,00 3,20 32,00 2,70 27,00 2,50 35,00 4,02
KITA AIR COLD 40,00 4,63 40,00 4,36 35,00 4,00 35,00 3,10 35,00 2,60 30,00 2,35 37,00 4,20
KITA AIR PLUS 48,00 4,81 47,00 4,20 45,00 3,84 42,00 3,04 35,00 2,65 31,00 2,45 39,00 4,00

KITA AIR electric heat pump Air/Air
Manuals 11.8 MB
Bukleti 2.2 MB
MULTI-AIR digital control panel for centralized control of KITA AIR heat pumps
Manuals 2 MB
Modelis: KITA AIR COLD
Mounting brackets
4.5.1.4 Metal legs for KITA AIR / KITA AIR COLD heat pump outdoor unit
4.5.1.4
Metal legs for KITA AIR / KITA AIR COLD heat pump outdoor unit
4.5.1.3+2.1.3.3 SBR rubber floor supports with required support brackets for KITA AIR / KITA AIR COLD heat pump outdoor unit, dimensions 250x130xH95 mm
4.5.1.3+2.1.3.3
SBR rubber floor supports with required support brackets for KITA AIR / KITA AIR COLD heat pump outdoor unit, dimensions 250x130xH95 mm
4.5.1.3+2.1.3.2 Wall brackets with required support brackets for KITA AIR / KITA AIR COLD heat pump outdoor unit, dimensions 1200x700 mm
4.5.1.3+2.1.3.2
Wall brackets with required support brackets for KITA AIR / KITA AIR COLD heat pump outdoor unit, dimensions 1200x700 mm
2.1.3.5 Wall brackets for KITA AIR / KITA AIR COLD / KITA AIR PLUS heat pump direct blowing indoor unit, dimensions 1000x450 mm
2.1.3.5
Wall brackets for KITA AIR / KITA AIR COLD / KITA AIR PLUS heat pump direct blowing indoor unit, dimensions 1000x450 mm
Controllers
K-TOUCH wall-mounted Digital control panel for KITA AIR heat pumps, 7" touch screen, delivered with surface mounted metal frame
K-TOUCH wall-mounted
Digital control panel for KITA AIR heat pumps, 7" touch screen, delivered with surface mounted metal frame
K-TOUCH flush-mounted Digital control panel for KITA AIR heat pumps, 7" touch screen, delivered with flush mounted frame
K-TOUCH flush-mounted
Digital control panel for KITA AIR heat pumps, 7" touch screen, delivered with flush mounted frame
MULTI-AIR Digital control panel for centralized control of KITA AIR heat pumps, can control up to 15 units (each controlled unit requires BMS BOARD electronic communication board), big 15.6" touch display
MULTI-AIR
Digital control panel for centralized control of KITA AIR heat pumps, can control up to 15 units (each controlled unit requires BMS BOARD electronic communication board), big 15.6" touch display
BMS BOARD Electronic communication board for KITA AIR heat pumps connection to MULTI-AIR control panel
BMS BOARD
Electronic communication board for KITA AIR heat pumps connection to MULTI-AIR control panel
Air filters
4.5.1.15 Air filtration kit for direct blowing indoor unit of KITA AIR / KITA AIR COLD / KITA AIR PLUS heat pump, consists of two filters and their supports, lateral filters replacement
4.5.1.15
Air filtration kit for direct blowing indoor unit of KITA AIR / KITA AIR COLD / KITA AIR PLUS heat pump, consists of two filters and their supports, lateral filters replacement
4.5.1.25 Air filtration kit for direct blowing indoor unit of KITA AIR / KITA AIR COLD / KITA AIR PLUS heat pump, consists of two filters and their supports, filters replacement from below
4.5.1.25
Air filtration kit for direct blowing indoor unit of KITA AIR / KITA AIR COLD / KITA AIR PLUS heat pump, consists of two filters and their supports, filters replacement from below
Electric heaters
4.4.1.2 9 kW power complementary electric heater for indoor unit of heat pump
4.4.1.2
9 kW power complementary electric heater for indoor unit of heat pump
4.4.1.3 13.5 kW power complementary electric heater for indoor unit of heat pump
4.4.1.3
13.5 kW power complementary electric heater for indoor unit of heat pump
Additional accessories for KITA AIR heat pumps
K.RSC Condensate drain pipe heater for outdoor unit of KITA AIR heat pump
K.RSC
Condensate drain pipe heater for outdoor unit of KITA AIR heat pump
4.5.6.2 Improved sound insulation for outdoor unit of KITA AIR / KITA AIR COLD heat pump (can be ordered with a new unit only)
4.5.6.2
Improved sound insulation for outdoor unit of KITA AIR / KITA AIR COLD heat pump (can be ordered with a new unit only)
4.5.1.9 Coil protection grid for outdoor unit of KITA AIR / KITA AIR COLD heat pump
4.5.1.9
Coil protection grid for outdoor unit of KITA AIR / KITA AIR COLD heat pump
Service
ORF PDDSS Oras-oras šilumos siurblio paleidimo-derinimo darbai (įrenginio elektrinės dalies, patikra; patalpos termostato veikimo patikrinimas; ventiliatorių apžiūra; šilumos siurblio sistemos apžiūra; kompresoriaus darbinių parametrų patikra, aukštos ir žemos pusės šaltnešio slėgio patikra; kondensatoriaus ir garintuvo apžiūra. Atliekant darbus už Kauno miesto ribų, transporto išlaidos skaičiuojamos papildomai 0,3 EUR/1 km.
ORF PDDSS
Oras-oras šilumos siurblio paleidimo-derinimo darbai (įrenginio elektrinės dalies, patikra; patalpos termostato veikimo patikrinimas; ventiliatorių apžiūra; šilumos siurblio sistemos apžiūra; kompresoriaus darbinių parametrų patikra, aukštos ir žemos pusės šaltnešio slėgio patikra; kondensatoriaus ir garintuvo apžiūra. Atliekant darbus už Kauno miesto ribų, transporto išlaidos skaičiuojamos papildomai 0,3 EUR/1 km.