Ūdens-gaisa aizkari, dedicated to operate with low temperature heating medium, horizontal and vertical mounting, housing made of powder coated steel, dynamically starting EC fans, automatic operating modes adapting to the weather conditions (OPTIsmart), protection class IP21, can be connected to BMS, max. mounting height 3.6 m , heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums: Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
ELiS AX36 - dedicated to operate with low temperature heating medium, horizontal and vertical mounting, housing made of powder coated steel, dynamically starting EC fans, automatic operating modes adapting to the weather conditions (OPTIsmart), protection class IP21, can be connected to BMS, max. mounting height 3.6 m
ELiS AX36-W3R-100 Heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY
ELiS AX36-W3R-100
Heating power at 60/40°C water and 18°C air temperature: from 8.1 kW at min. airflow to 12.9 kW at max. airflow, temperature increase ΔT 26-21°C, 3 row heat exchanger, air flow 900-1800 m³/h, max. electrical power consumption 270 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 38.5 kg, 2 year WARRANTY
ELiS AX36-W3R-150 Heating power at 60/40°C water and 18°C air temperature: from 11.8 kW at min. airflow to 20.5 kW at max. airflow, temperature increase ΔT 29-22°C, 3 row heat exchanger, air flow 1200-2700 m³/h, max. electrical power consumption 400 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 53.3 kg, 2 year WARRANTY
ELiS AX36-W3R-150
Heating power at 60/40°C water and 18°C air temperature: from 11.8 kW at min. airflow to 20.5 kW at max. airflow, temperature increase ΔT 29-22°C, 3 row heat exchanger, air flow 1200-2700 m³/h, max. electrical power consumption 400 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 53.3 kg, 2 year WARRANTY
ELiS AX36-W3R-200 Heating power at 60/40°C water and 18°C air temperature: from 17.1 kW at min. airflow to 29.0 kW at max. airflow, temperature increase ΔT 25-20°C, 3 row heat exchanger, air flow 2000-4300 m³/h, max. electrical power consumption 670 W, acoustic pressure level 45-63 dB(A), covered door gap 2 m, weight 71.7 kg, 2 year WARRANTY
ELiS AX36-W3R-200
Heating power at 60/40°C water and 18°C air temperature: from 17.1 kW at min. airflow to 29.0 kW at max. airflow, temperature increase ΔT 25-20°C, 3 row heat exchanger, air flow 2000-4300 m³/h, max. electrical power consumption 670 W, acoustic pressure level 45-63 dB(A), covered door gap 2 m, weight 71.7 kg, 2 year WARRANTY
ELiS AX36-W3R-250 Heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY
ELiS AX36-W3R-250
Heating power at 60/40°C water and 18°C air temperature: from 21.4 kW at min. airflow to 38.0 kW at max. airflow, temperature increase ΔT 27-21°C, 3 row heat exchanger, air flow 2300-5300 m³/h, max. electrical power consumption 810 W, acoustic pressure level 46-64 dB(A), covered door gap 2.5 m, weight 86.8 kg, 2 year WARRANTY
ELiS AX36-W4R-100 Heating power at 60/40°C water and 18°C air temperature: from 8.7 kW at min. airflow to 15.2 kW at max. airflow, temperature increase ΔT 32-26°C, 4 row heat exchanger, air flow 800-1700 m³/h, max. electrical power consumption 270 W, acoustic pressure level 41-59 dB(A), covered door gap 1 m, weight 40.0 kg, 2 year WARRANTY
ELiS AX36-W4R-100
Heating power at 60/40°C water and 18°C air temperature: from 8.7 kW at min. airflow to 15.2 kW at max. airflow, temperature increase ΔT 32-26°C, 4 row heat exchanger, air flow 800-1700 m³/h, max. electrical power consumption 270 W, acoustic pressure level 41-59 dB(A), covered door gap 1 m, weight 40.0 kg, 2 year WARRANTY
ELiS AX36-W4R-150 Heating power at 60/40°C water and 18°C air temperature: from 12.7 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 34-27°C, 4 row heat exchanger, air flow 1100-2600 m³/h, max. electrical power consumption 400 W, acoustic pressure level 42-60 dB(A), covered door gap 1.5 m, weight 55.6 kg, 2 year WARRANTY
ELiS AX36-W4R-150
Heating power at 60/40°C water and 18°C air temperature: from 12.7 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 34-27°C, 4 row heat exchanger, air flow 1100-2600 m³/h, max. electrical power consumption 400 W, acoustic pressure level 42-60 dB(A), covered door gap 1.5 m, weight 55.6 kg, 2 year WARRANTY
ELiS AX36-W4R-200 Heating power at 60/40°C water and 18°C air temperature: from 20.6 kW at min. airflow to 36.7 kW at max. airflow, temperature increase ΔT 31-26°C, 4 row heat exchanger, air flow 1900-4200 m³/h, max. electrical power consumption 670 W, acoustic pressure level 44-62 dB(A), covered door gap 2 m, weight 74.8 kg, 2 year WARRANTY
ELiS AX36-W4R-200
Heating power at 60/40°C water and 18°C air temperature: from 20.6 kW at min. airflow to 36.7 kW at max. airflow, temperature increase ΔT 31-26°C, 4 row heat exchanger, air flow 1900-4200 m³/h, max. electrical power consumption 670 W, acoustic pressure level 44-62 dB(A), covered door gap 2 m, weight 74.8 kg, 2 year WARRANTY
ELiS AX36-W4R-250 Heating power at 60/40°C water and 18°C air temperature: from 24.7 kW at min. airflow to 46.6 kW at max. airflow, temperature increase ΔT 33-26°C, 4 row heat exchanger, air flow 2200-5200 m³/h, max. electrical power consumption 810 W, acoustic pressure level 45-63 dB(A), covered door gap 2.5 m, weight 90.3 kg, 2 year WARRANTY
ELiS AX36-W4R-250
Heating power at 60/40°C water and 18°C air temperature: from 24.7 kW at min. airflow to 46.6 kW at max. airflow, temperature increase ΔT 33-26°C, 4 row heat exchanger, air flow 2200-5200 m³/h, max. electrical power consumption 810 W, acoustic pressure level 45-63 dB(A), covered door gap 2.5 m, weight 90.3 kg, 2 year WARRANTY
ELiS AX45 - dedicated to operate with low temperature heating medium, horizontal and vertical mounting, housing made of powder coated steel, dynamically starting EC fans, automatic operating modes adapting to the weather conditions (OPTIsmart), protection class IP21, can be connected to BMS, max. mounting height 4.5 m
ELiS AX45-W3R-100 Heating power at 60/40°C water and 18°C air temperature: from 9.3 kW at min. airflow to 15.7 kW at max. airflow, temperature increase ΔT 25-18°C, 3 row heat exchanger, air flow 1100-2500 m³/h, max. electrical power consumption 490 W, acoustic pressure level 43-61 dB(A), covered door gap 1 m, weight 40.8 kg, 2 year WARRANTY
ELiS AX45-W3R-100
Heating power at 60/40°C water and 18°C air temperature: from 9.3 kW at min. airflow to 15.7 kW at max. airflow, temperature increase ΔT 25-18°C, 3 row heat exchanger, air flow 1100-2500 m³/h, max. electrical power consumption 490 W, acoustic pressure level 43-61 dB(A), covered door gap 1 m, weight 40.8 kg, 2 year WARRANTY
ELiS AX45-W3R-150 Heating power at 60/40°C water and 18°C air temperature: from 13.9 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 1500-3500 m³/h, max. electrical power consumption 650 W, acoustic pressure level 44-62 dB(A), covered door gap 1.5 m, weight 55.5 kg, 2 year WARRANTY
ELiS AX45-W3R-150
Heating power at 60/40°C water and 18°C air temperature: from 13.9 kW at min. airflow to 24.1 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 1500-3500 m³/h, max. electrical power consumption 650 W, acoustic pressure level 44-62 dB(A), covered door gap 1.5 m, weight 55.5 kg, 2 year WARRANTY
ELiS AX45-W3R-200 Heating power at 60/40°C water and 18°C air temperature: from 18.4 kW at min. airflow to 31.8 kW at max. airflow, temperature increase ΔT 24-19°C, 3 row heat exchanger, air flow 2200-5000 m³/h, max. electrical power consumption 990 W, acoustic pressure level 45-64 dB(A), covered door gap 2 m, weight 73.7 kg, 2 year WARRANTY
ELiS AX45-W3R-200
Heating power at 60/40°C water and 18°C air temperature: from 18.4 kW at min. airflow to 31.8 kW at max. airflow, temperature increase ΔT 24-19°C, 3 row heat exchanger, air flow 2200-5000 m³/h, max. electrical power consumption 990 W, acoustic pressure level 45-64 dB(A), covered door gap 2 m, weight 73.7 kg, 2 year WARRANTY
ELiS AX45-W3R-250 Heating power at 60/40°C water and 18°C air temperature: from 22.1 kW at min. airflow to 41.4 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 2400-6100 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 46-65 dB(A), covered door gap 2.5 m, weight 88.8 kg, 2 year WARRANTY
ELiS AX45-W3R-250
Heating power at 60/40°C water and 18°C air temperature: from 22.1 kW at min. airflow to 41.4 kW at max. airflow, temperature increase ΔT 27-20°C, 3 row heat exchanger, air flow 2400-6100 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 46-65 dB(A), covered door gap 2.5 m, weight 88.8 kg, 2 year WARRANTY
ELiS AX45-W4R-100 Heating power at 60/40°C water and 18°C air temperature: from 10.3 kW at min. airflow to 19.1 kW at max. airflow, temperature increase ΔT 30-23°C, 4 row heat exchanger, air flow 1000-2400 m³/h, max. electrical power consumption 490 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 42.3 kg, 2 year WARRANTY
ELiS AX45-W4R-100
Heating power at 60/40°C water and 18°C air temperature: from 10.3 kW at min. airflow to 19.1 kW at max. airflow, temperature increase ΔT 30-23°C, 4 row heat exchanger, air flow 1000-2400 m³/h, max. electrical power consumption 490 W, acoustic pressure level 42-60 dB(A), covered door gap 1 m, weight 42.3 kg, 2 year WARRANTY
ELiS AX45-W4R-150 Heating power at 60/40°C water and 18°C air temperature: from 15.3 kW at min. airflow to 28.9 kW at max. airflow, temperature increase ΔT 32-25°C, 4 row heat exchanger, air flow 1400-3400 m³/h, max. electrical power consumption 650 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 57.8 kg, 2 year WARRANTY
ELiS AX45-W4R-150
Heating power at 60/40°C water and 18°C air temperature: from 15.3 kW at min. airflow to 28.9 kW at max. airflow, temperature increase ΔT 32-25°C, 4 row heat exchanger, air flow 1400-3400 m³/h, max. electrical power consumption 650 W, acoustic pressure level 43-61 dB(A), covered door gap 1.5 m, weight 57.8 kg, 2 year WARRANTY
ELiS AX45-W4R-200 Heating power at 60/40°C water and 18°C air temperature: from 22.2 kW at min. airflow to 40.6 kW at max. airflow, temperature increase ΔT 31-24°C, 4 row heat exchanger, air flow 2100-4900 m³/h, max. electrical power consumption 990 W, acoustic pressure level 44-63 dB(A), covered door gap 2 m, weight 76.8 kg, 2 year WARRANTY
ELiS AX45-W4R-200
Heating power at 60/40°C water and 18°C air temperature: from 22.2 kW at min. airflow to 40.6 kW at max. airflow, temperature increase ΔT 31-24°C, 4 row heat exchanger, air flow 2100-4900 m³/h, max. electrical power consumption 990 W, acoustic pressure level 44-63 dB(A), covered door gap 2 m, weight 76.8 kg, 2 year WARRANTY
ELiS AX45-W4R-250 Heating power at 60/40°C water and 18°C air temperature: from 25.6 kW at min. airflow to 51.3 kW at max. airflow, temperature increase ΔT 33-25°C, 4 row heat exchanger, air flow 2300-6000 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 45-64 dB(A), covered door gap 2.5 m, weight 92.3 kg, 2 year WARRANTY
ELiS AX45-W4R-250
Heating power at 60/40°C water and 18°C air temperature: from 25.6 kW at min. airflow to 51.3 kW at max. airflow, temperature increase ΔT 33-25°C, 4 row heat exchanger, air flow 2300-6000 m³/h, max. electrical power consumption 1150 W, acoustic pressure level 45-64 dB(A), covered door gap 2.5 m, weight 92.3 kg, 2 year WARRANTY
Modelis: ELiS AX36-W3R-250
Vispārējie dati
Sildīšanas jauda pie 60/40°C ūdens un 18°C gaisa temperatūras, fan at max speed
kW
38,0
Sildīšanas jauda pie 60/40°C ūdens un 18°C gaisa temperatūras, fan at min speed
kW
21,4
Air temperature rise ΔT at 60/40°C water and 18°C air temperature, fan at max speed
°C
21
Air temperature rise ΔT at 60/40°C water and 18°C air temperature, fan at min speed
°C
27
Gaisa pūšanas attālums
m
3,6
Maks. gaisa plūsma
m³/st.
5300
Ventilatora dati
Gaisa plūsma
m³/st.
2300 - 5300
Acoustic pressure level at a distance of 2 m from the unit, in the 1500 m³ room of medium capabillity of sound absorption
dB(A)
46 - 64
Ventilatora tips
EC
Instalācijas dati
Elektrības padeve
V/Hz
230/50
Maks. enerģijas patēriņš
W
810
Maks. strāvas patēriņš
A
6,4
IP aizsardzības klase
21
Montēšana
Horizontal & vertical
Maks. darba temperatūru telpā
°C
30
Apkurei izmantojamā ūdens maks. temperatūra
°C
60
Maks. darba spiediens
MPa
1,6
Ūdens cauruļu pievienošana
Ø "
3/4
Citi dati
Number of rows of the heat exchanger
3
Izmēri
Garums
mm
2623
Dziļums
mm
670
Augstums
mm
293
Svars
kg
86,8

Izmēri

Modelis: ELiS AX36-W3R-250
ELiS AX gaisa aizkari
Bukleti 1016 KB
Modelis: ELiS AX36-W3R-250
Montāžas kronšteini
KRON AX H 250 Kronšteins ELiS AX 250 gaisa aizkariem
KRON AX H 250
Kronšteins ELiS AX 250 gaisa aizkariem
KRON AX V Kronšteins vertikālajiem ELiS AX gaisa aizkariem
KRON AX V
Kronšteins vertikālajiem ELiS AX gaisa aizkariem
Vadības sistēmas gaisa aizkariem
DCe Magnētiskais durvju slēdzis
DCe
Magnētiskais durvju slēdzis
DCm Mehāniskais durvju slēdzis
DCm
Mehāniskais durvju slēdzis
FLOWAIR vadības sistēma
T-box Zone Intelligent controller with touch screen, built-in room thermostat and programable week calendar, one controller can control up to 31 units, multi-zone control - can create up to 31 zones and control each unit independently, can be connected to BMS
T-box Zone
Intelligent controller with touch screen, built-in room thermostat and programable week calendar, one controller can control up to 31 units, multi-zone control - can create up to 31 zones and control each unit independently, can be connected to BMS
PT-1000 Temperatūras sensors DRV vadības moduļiem, IP65
PT-1000
Temperatūras sensors DRV vadības moduļiem, IP65
Vārsti
SRX20 2D 0-10V Modulating two-way valve with transformer, 3/4" connection, 0-10V input
SRX20 2D 0-10V
Modulating two-way valve with transformer, 3/4" connection, 0-10V input
SRX32 2D 0-10V Modulating two-way valve with transformer, 1¼" connection, 0-10V input
SRX32 2D 0-10V
Modulating two-way valve with transformer, 1¼" connection, 0-10V input
SRX20 2D 3P Two-way valve with 3 point actuator, 3/4" connection
SRX20 2D 3P
Two-way valve with 3 point actuator, 3/4" connection
Vibrācijas slāpējošas savienošanas caurules ar nerūsējošā tērauda stiegrojuma vijumu
ZAR 100 3/4 Ø19 Vibrācijas slāpējoša savienošanas caurule, 100 cm garums, 3/4" collu savienojums, Ø19 mm diametrs
ZAR 100 3/4 Ø19
Vibrācijas slāpējoša savienošanas caurule, 100 cm garums, 3/4" collu savienojums, Ø19 mm diametrs
Papildu piederumi gaisa aizkariem
FILTER AX 250 Set of filters for ELiS AX 250 air curtain (Coarse 30%)
FILTER AX 250
Set of filters for ELiS AX 250 air curtain (Coarse 30%)