Fan coil, without casing, for horizontal concealed mounting inside ceiling, rear air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection, 2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
PS-UWL 2T - without casing, for horizontal concealed mounting inside ceiling, rear air intake, three-speed AC type centrifugal fan with static pressure up to 50 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWL 2T 040 3.32/3.52/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWL 2T 040
3.32/3.52/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWL 2T 060 3.78/3.92/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWL 2T 060
3.78/3.92/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWL 2T 090 6.97/7.22/7.58 kW heating capacity or 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWL 2T 090
6.97/7.22/7.58 kW heating capacity or 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWL 2T 120 8.84/9.67/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWL 2T 120
8.84/9.67/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWL 4T - without casing, for horizontal concealed mounting inside ceiling, rear air intake, three-speed AC type centrifugal fan with static pressure up to 50 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWL 4T 044 3.18/3.31/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWL 4T 044
3.18/3.31/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWL 4T 064 3.92/4.09/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWL 4T 064
3.92/4.09/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWL 4T 094 6.62/6.80/7.09 kW heating capacity in 1 row heat exchanger and 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWL 4T 094
6.62/6.80/7.09 kW heating capacity in 1 row heat exchanger and 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWL 4T 124 9.15/9.80/10.15 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWL 4T 124
9.15/9.80/10.15 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLF 2T - without casing, for horizontal concealed mounting inside ceiling, bottom air intake, three-speed AC type centrifugal fan with static pressure up to 50 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWLF 2T 040 3.32/3.52/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLF 2T 040
3.32/3.52/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLF 2T 060 3.78/3.92/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLF 2T 060
3.78/3.92/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLF 2T 090 6.97/7.22/7.58 kW heating capacity or 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLF 2T 090
6.97/7.22/7.58 kW heating capacity or 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLF 2T 120 8.84/9.67/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLF 2T 120
8.84/9.67/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLF 4T - without casing, for horizontal concealed mounting inside ceiling, bottom air intake, three-speed AC type centrifugal fan with static pressure up to 50 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWLF 4T 044 3.18/3.31/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLF 4T 044
3.18/3.31/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLF 4T 064 3.92/4.09/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLF 4T 064
3.92/4.09/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLF 4T 094 6.62/6.80/7.09 kW heating capacity in 1 row heat exchanger and 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLF 4T 094
6.62/6.80/7.09 kW heating capacity in 1 row heat exchanger and 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLF 4T 124 9.15/9.80/10.15 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLF 4T 124
9.15/9.80/10.15 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLV 2T - without casing, for vertical concealed mounting inside wall, bottom air intake, three-speed AC type centrifugal fan with static pressure up to 50 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWLV 2T 040 3.32/3.52/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLV 2T 040
3.32/3.52/3.66 kW heating capacity or 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLV 2T 060 3.78/3.92/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLV 2T 060
3.78/3.92/4.32 kW heating capacity or 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLV 2T 090 6.97/7.22/7.58 kW heating capacity or 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLV 2T 090
6.97/7.22/7.58 kW heating capacity or 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLV 2T 120 8.84/9.67/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLV 2T 120
8.84/9.67/10.22 kW heating capacity or 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLV 4T - without casing, for vertical concealed mounting inside wall, bottom air intake, three-speed AC type centrifugal fan with static pressure up to 50 Pa, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWLV 4T 044 3.18/3.31/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLV 4T 044
3.18/3.31/3.47 kW heating capacity in 1 row heat exchanger and 2.07/2.63/2.86 kW cooling capacity in 3 row heat exchanger, air flow 295/395/445 m³/h, sound pressure level 25/33/36 dB(A), max. fan power 86 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLV 4T 064 3.92/4.09/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLV 4T 064
3.92/4.09/4.32 kW heating capacity in 1 row heat exchanger and 2.63/3.25/3.67 kW cooling capacity in 3 row heat exchanger, air flow 325/420/490 m³/h, sound pressure level 23/31/35 dB(A), max. fan power 87 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLV 4T 094 6.62/6.80/7.09 kW heating capacity in 1 row heat exchanger and 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLV 4T 094
6.62/6.80/7.09 kW heating capacity in 1 row heat exchanger and 5.09/6.05/6.51 kW cooling capacity in 3 row heat exchanger, air flow 655/810/895 m³/h, sound pressure level 25/35/39 dB(A), max. fan power 194 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLV 4T 124 9.15/9.80/10.15 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLV 4T 124
9.15/9.80/10.15 kW heating capacity in 1 row heat exchanger and 5.87/7.67/8.78 kW cooling capacity in 3 row heat exchanger, air flow 725/1000/1185 m³/h, sound pressure level 30/37/41 dB(A), max. fan power 209 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLE 2T - without casing, for horizontal concealed mounting inside ceiling, rear air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWLE 2T 040 1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLE 2T 040
1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLE 2T 060 1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLE 2T 060
1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLE 2T 090 1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLE 2T 090
1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLE 2T 120 2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLE 2T 120
2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLE 4T - without casing, for horizontal concealed mounting inside ceiling, rear air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWLE 4T 044 1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/41 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLE 4T 044
1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/41 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLE 4T 064 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLE 4T 064
1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLE 4T 094 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLE 4T 094
1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLE 4T 124 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLE 4T 124
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEF 2T - without casing, for horizontal concealed mounting inside ceiling, bottom air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWLEF 2T 040 1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEF 2T 040
1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEF 2T 060 1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEF 2T 060
1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEF 2T 090 1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEF 2T 090
1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEF 2T 120 2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEF 2T 120
2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEF 4T - without casing, for horizontal concealed mounting inside ceiling, bottom air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWLEF 4T 044 1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/41 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEF 4T 044
1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/41 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEF 4T 064 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEF 4T 064
1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEF 4T 094 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEF 4T 094
1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEF 4T 124 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEF 4T 124
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEV 2T - without casing, for vertical concealed mounting inside wall, bottom air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWLEV 2T 040 1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEV 2T 040
1.13/2.28/3.22 kW heating capacity or 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEV 2T 060 1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEV 2T 060
1.51/3.03/4.22 kW heating capacity or 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEV 2T 090 1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEV 2T 090
1.76/3.85/5.87 kW heating capacity or 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEV 2T 120 2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEV 2T 120
2.79/5.84/8.08 kW heating capacity or 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEV 4T - without casing, for vertical concealed mounting inside wall, bottom air intake, EC type centrifugal fan with static pressure up to 90 Pa, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWLEV 4T 044 1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/41 dB(A), max. fan power 49 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEV 4T 044
1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 0.89/1.43/2.33 kW cooling capacity in 3 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/41 dB(A), max. fan power 49 W, dimensions 540x230xH440 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLEV 4T 064 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEV 4T 064
1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.16/2.30/3.25 kW cooling capacity in 3 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 740x230xH440 mm, weight 20.9 kg, 2 year WARRANTY
PS-UWLEV 4T 094 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEV 4T 094
1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.44/3.14/4.75 kW cooling capacity in 3 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/39 dB(A), max. fan power 61 W, dimensions 940x230xH440 mm, weight 25.1 kg, 2 year WARRANTY
PS-UWLEV 4T 124 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLEV 4T 124
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 2.18/4.67/6.45 kW cooling capacity in 3 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/43 dB(A), max. fan power 100 W, dimensions 1140x230xH440 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLES 2T - without casing, for horizontal concealed mounting inside ceiling, rear air intake, silenced version for places that require a low noise level, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-UWLES 2T 040/4R 1.38/3.21/4.51 kW heating capacity or 1.28/2.77/3.81 kW cooling capacity in 4 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLES 2T 040/4R
1.38/3.21/4.51 kW heating capacity or 1.28/2.77/3.81 kW cooling capacity in 4 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLES 2T 060/4R 1.70/3.68/5.35 kW heating capacity or 1.70/3.48/4.84 kW cooling capacity in 4 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 21 kg, 2 year WARRANTY
PS-UWLES 2T 060/4R
1.70/3.68/5.35 kW heating capacity or 1.70/3.48/4.84 kW cooling capacity in 4 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 21 kg, 2 year WARRANTY
PS-UWLES 2T 090/4R 1.91/4.56/7.33 kW heating capacity or 1.96/4.39/6.77 kW cooling capacity in 4 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/38 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25 kg, 2 year WARRANTY
PS-UWLES 2T 090/4R
1.91/4.56/7.33 kW heating capacity or 1.96/4.39/6.77 kW cooling capacity in 4 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/38 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25 kg, 2 year WARRANTY
PS-UWLES 2T 120/4R 3.07/6.99/10.08 kW heating capacity or 3.16/6.77/9.52 kW cooling capacity in 4 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/38 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLES 2T 120/4R
3.07/6.99/10.08 kW heating capacity or 3.16/6.77/9.52 kW cooling capacity in 4 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/38 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLES 4T - without casing, for horizontal concealed mounting inside ceiling, rear air intake, silenced version for places that require a low noise level, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-UWLES 4T 044/4R 1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 1.28/2.77/3.81 kW cooling capacity in 4 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLES 4T 044/4R
1.20/2.25/2.91 kW heating capacity in 1 row heat exchanger and 1.28/2.77/3.81 kW cooling capacity in 4 row heat exchanger, air flow 142/355/528 m³/h, sound pressure level 24/34/40 dB(A), max. fan power 49 W, dimensions 700x440xH230 mm, weight 17.5 kg, 2 year WARRANTY
PS-UWLES 4T 064/4R 1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.70/3.48/4.84 kW cooling capacity in 4 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 21 kg, 2 year WARRANTY
PS-UWLES 4T 064/4R
1.62/2.81/3.69 kW heating capacity in 1 row heat exchanger and 1.70/3.48/4.84 kW cooling capacity in 4 row heat exchanger, air flow 172/382/572 m³/h, sound pressure level 24/32/41 dB(A), max. fan power 52 W, dimensions 900x440xH230 mm, weight 21 kg, 2 year WARRANTY
PS-UWLES 4T 094/4R 1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.96/4.39/6.77 kW cooling capacity in 4 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/38 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25 kg, 2 year WARRANTY
PS-UWLES 4T 094/4R
1.87/3.49/4.93 kW heating capacity in 1 row heat exchanger and 1.96/4.39/6.77 kW cooling capacity in 4 row heat exchanger, air flow 193/470/783 m³/h, sound pressure level 24/30/38 dB(A), max. fan power 61 W, dimensions 1100x440xH230 mm, weight 25 kg, 2 year WARRANTY
PS-UWLES 4T 124/4R 3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 3.16/6.77/9.52 kW cooling capacity in 4 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/38 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWLES 4T 124/4R
3.09/5.58/7.29 kW heating capacity in 1 row heat exchanger and 3.16/6.77/9.52 kW cooling capacity in 4 row heat exchanger, air flow 310/720/1064 m³/h, sound pressure level 24/34/38 dB(A), max. fan power 100 W, dimensions 1300x440xH230 mm, weight 34.5 kg, 2 year WARRANTY
PS-UWL / PS-UWLE / PS-UWLV / PS-UWLEV / PS-UWLF / PS-UWLEF standard concealed fan coil units
Manuals 1.5 MB
Bukleti 1.3 MB
Katalogi 3.3 MB
PS-UWLES silenced version of concealed fan coil units
Manuals 1.5 MB
Bukleti 993 KB
Katalogi 602 KB
TEL wireless remote control panel
Manuals 254 KB
Fan coils controllers
Bukleti 8.1 MB
Modelis: PS-UWLE 2T 120
Control panels for fan coils
TER.EC.ANA Suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.ANA
Suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.DIG Suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, possibility to remotely turn device on/off, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.DIG
Suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, possibility to remotely turn device on/off, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BUS Suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BUS
Suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units
TER.EC.BAC Suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
TER.EC.BAC
Suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
TER.EC.TOUCH Suitable for 2-pipe units with EC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor , Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH 2T, PS-CLE/CLES/CLEH 2T, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED 2T, PS-DCE/HDCE 2T units
TER.EC.TOUCH
Suitable for 2-pipe units with EC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor , Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH 2T, PS-CLE/CLES/CLEH 2T, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED 2T, PS-DCE/HDCE 2T units
TEL Wireless, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, for use with PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory
TEL
Wireless, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, for use with PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory
Accessories for fan coils controls
KIT.TEL.EC Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
KIT.TEL.EC
Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units
KIT.WI-FI.EC Electronic board for PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan control via Wi-Fi, delivered with air temperature probe
KIT.WI-FI.EC
Electronic board for PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan control via Wi-Fi, delivered with air temperature probe
KIT.BUS Electronic board for PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe
KIT.BUS
Electronic board for PS-CL/CLE/CLES/CLH/CLEH, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe
DIS.BUS Information screen to display data from device controlled via KIT.BUS electronic board
DIS.BUS
Information screen to display data from device controlled via KIT.BUS electronic board
SM Supply water temperature sensor for automatic summer/winter mode change-over in control panels, to be used with single coil units without valve or with 3-way valve
SM
Supply water temperature sensor for automatic summer/winter mode change-over in control panels, to be used with single coil units without valve or with 3-way valve
TM Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with control panels
TM
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with control panels
Water valves
ATT.230 On/Off actuator for water valve, powered by 230 V
ATT.230
On/Off actuator for water valve, powered by 230 V
ATT.24 On/Off actuator for water valve, powered by 24 V
ATT.24
On/Off actuator for water valve, powered by 24 V
ATT.230.M On/Off actuator for water valve, powered by 230 V, with limit switch
ATT.230.M
On/Off actuator for water valve, powered by 230 V, with limit switch
ATT.24.M On/Off actuator for water valve, powered by 24 V, with limit switch
ATT.24.M
On/Off actuator for water valve, powered by 24 V, with limit switch
ATT.MOD Modulating by 0-10 V signal actuator for water valve
ATT.MOD
Modulating by 0-10 V signal actuator for water valve
VAL.2V.34.UWL 2-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 120 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for cooling, 3/4" connection
VAL.2V.34.UWL
2-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 120 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for cooling, 3/4" connection
VAL.3V.34.UWL 3-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 120 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for cooling, 3/4" connection
VAL.3V.34.UWL
3-way water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 120 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for cooling, 3/4" connection
VAL.34.DIN.UWL Balancing water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 120 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for cooling, 3/4" connection
VAL.34.DIN.UWL
Balancing water valve for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, for 120 size units it is used for heating and cooling, for 4 pipe 124 size units it is used only for cooling, 3/4" connection
Condensate drain pumps
POM.CON.20.UWL Condensate drain pump for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, flow rate 20 l/h
POM.CON.20.UWL
Condensate drain pump for PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, flow rate 20 l/h
Air inlet / outlet spigot plenums
PLE.CIR.120 Air inlet / outlet spigot plenum for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coils, quantity of spigots 3 pcs., diameter of spigots Ø150 mm
PLE.CIR.120
Air inlet / outlet spigot plenum for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coils, quantity of spigots 3 pcs., diameter of spigots Ø150 mm
Air inlet / outlet adjustable length telescopic plenums
TLDCT.120 Air inlet / outlet adjustable length telescopic plenum for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
TLDCT.120
Air inlet / outlet adjustable length telescopic plenum for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
Air supply grilles
GRM.120 Aluminium air supply grille with adjustable fins for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
GRM.120
Aluminium air supply grille with adjustable fins for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
GRMB.120 Aluminium air supply grille with fixed fins for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
GRMB.120
Aluminium air supply grille with fixed fins for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
Air intake grilles
GRA.120 Aluminium air intake grille for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
GRA.120
Aluminium air intake grille for 120 / 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 160x1090 mm
GRF.90120 Aluminium air intake grille with G3 class filter for 090 - 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 400x600 mm
GRF.90120
Aluminium air intake grille with G3 class filter for 090 - 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units, dimensions 400x600 mm
Antibacterial UV LED lamps
LAM.UV.LED.90120 Antibacterial UV LED lamp for 090 - 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units
LAM.UV.LED.90120
Antibacterial UV LED lamp for 090 - 124 size PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES fan coil units
Painting in non-standard colors
GRM-V-UWL Painting of GRM / GRMB UWL air supply grille in non-standard RAL color
GRM-V-UWL
Painting of GRM / GRMB UWL air supply grille in non-standard RAL color
GRA-V-UWL Painting of GRA UWL air intake grille in non-standard RAL color
GRA-V-UWL
Painting of GRA UWL air intake grille in non-standard RAL color
GRF-V-UWL Painting of GRF UWL air intake grille in non-standard RAL color
GRF-V-UWL
Painting of GRF UWL air intake grille in non-standard RAL color