|
TER.EC.ANA |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units |
|
TER.EC.ANA |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor SM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units |
|
TER.EC.DIG |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units |
|
TER.EC.DIG |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional SM sensor, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units |
|
TER.EC.BUS |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units |
|
TER.EC.BUS |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via Modbus RTU protocol, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE units |
|
TER.EC.BAC |
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units |
|
TER.EC.BAC |
|
Control panel, suitable for 2-pipe and 4-pipe units with EC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional TM sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor SM, possibility to connect supply hot water detection temperature sensor TM, RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FSE, PS-FLE/FLEF/FLEH, PS-CLE/CLES/CLEH/CLEHS, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units |
|
TER.EC.TOUCH |
Control panel, suitable for 2-pipe units with EC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor SM, Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH 2T, PS-CLE/CLES/CLEH/CLEHS 2T, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED 2T, PS-DCE/HDCE 2T units |
|
TER.EC.TOUCH |
|
Control panel, suitable for 2-pipe units with EC fans, touch screen, manual and automatic 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, programmable weekly calendar, on/off valves control, possibility to connect remote air sensor SM, Wi-Fi connection for possibility to control the device remotely through the app for smart Android / IOS devices, for use with PS-WLE, PS-FSE, PS-FLE/FLEF/FLEH 2T, PS-CLE/CLES/CLEH/CLEHS 2T, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED 2T, PS-DCE/HDCE 2T units |
|
TEL |
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH/CLEHS, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory |
|
TEL |
|
Wireless control panel, suitable for 2-pipe and 4-pipe units, LCD display, manual and automatic 3 steps fan speed selection, manual summer/winter mode, on/off valves control, possibility to connect supply hot water detection temperature sensor TM, for use with PS-CL/CLE/CLES/CLH/CLEH/CLEHS, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES, PS-DC/DCE/HDC/HDCE units, required to use together with KIT.TEL or KIT.TEL.EC accessory |
|
KIT.TEL.EC |
Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units |
|
KIT.TEL.EC |
|
Wireless control panel signal receiver and PCB together with temperature probe, for installation inside fan coil unit with EC type fan, fits to PS-CLE/CLES/CLEH, PS-UWLE/UWLEF/UWLEV/UWLES, PS-DCE/HDCE units |
|
KIT.WI-FI.EC |
Electronic board for remote control of PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe |
|
KIT.WI-FI.EC |
|
Electronic board for remote control of PS-FSE, PS-FLE/FLEF/FLEH, PS-UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DCE/HDCE fan coil units with EC type fan via Wi-Fi connection and app for smart Android / IOS devices, delivered with air temperature probe |
|
KIT.BUS |
Electronic board for PS-CL/CLE/CLES/CLH/CLEH/CLQ, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe |
|
KIT.BUS |
|
Electronic board for PS-CL/CLE/CLES/CLH/CLEH/CLQ, PS-UWL/UWLF/UWLV/UWLE/UWLEF/UWLEV/UWLES/UWLED, PS-DC/DCE/HDC/HDCE fan coil units connection to BMS via Mod-Bus protocol, delivered with air temperature probe |
|
DIS.BUS |
Information screen to display data from device controlled via KIT.BUS electronic board |
|
DIS.BUS |
|
Information screen to display data from device controlled via KIT.BUS electronic board |
|
SM |
Temperature sensor for automatic summer/winter mode change-over in TER.DIG.S / TER.EC.DIG control panels (to be used with units without valve or with 3-way valve), it also can be used as a remote air temperature sensor for TER.ANA(.M) / TER.ANA.S(.M) / TER.EC.ANA(.M) / TER.DIG(.M) / TER.DIG.S / TER.EC.DIG(.M) / TER.BUS(.M) / TER.BAC(.M) / TER.EC.BUS(.M) / TER.EC.BAC / TER.TOUCH(.M) / TER.EC.TOUCH(.M) control panels |
|
SM |
|
Temperature sensor for automatic summer/winter mode change-over in TER.DIG.S / TER.EC.DIG control panels (to be used with units without valve or with 3-way valve), it also can be used as a remote air temperature sensor for TER.ANA(.M) / TER.ANA.S(.M) / TER.EC.ANA(.M) / TER.DIG(.M) / TER.DIG.S / TER.EC.DIG(.M) / TER.BUS(.M) / TER.BAC(.M) / TER.EC.BUS(.M) / TER.EC.BAC / TER.TOUCH(.M) / TER.EC.TOUCH(.M) control panels |
|
TM |
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.ANA.S / TER.ANA.S.M / TER.DIG.S / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TEL control panels |
|
TM |
|
Supply hot water detection (35°C) temperature sensor for turning on fan coil unit in heating mode only when hot water is flowing, to be used with units without valve or with 3-way valve, usable with TER.ANA.S / TER.ANA.S.M / TER.DIG.S / TER.EC.DIG / TER.EC.DIG.M / TER.BUS / TER.BUS.M / TER.BAC / TER.BAC.M / TER.EC.BUS / TER.EC.BUS.M / TER.EC.BAC / TEL control panels |
|
ATT.230 |
On/Off actuator for water valve, powered by 230 V |
|
ATT.230 |
|
On/Off actuator for water valve, powered by 230 V |
|
ATT.230.M |
On/Off actuator for water valve, powered by 230 V, with limit switch |
|
ATT.230.M |
|
On/Off actuator for water valve, powered by 230 V, with limit switch |
|
ATT.MOD |
Modulating by 0-10 V signal actuator for water valve |
|
ATT.MOD |
|
Modulating by 0-10 V signal actuator for water valve |
|
VAL.2V.10.DC |
2-way water valve for PS-DC/DCE fan coil units, for 2 pipe units it is used for heating and cooling, for 4 pipe units it is used only for cooling, 1" connection |
|
VAL.2V.10.DC |
|
2-way water valve for PS-DC/DCE fan coil units, for 2 pipe units it is used for heating and cooling, for 4 pipe units it is used only for cooling, 1" connection |
|
VAL.3V.10.DC |
3-way water valve for PS-DC/DCE fan coil units, for 2 pipe units it is used for heating and cooling, for 4 pipe units it is used only for cooling, 1" connection |
|
VAL.3V.10.DC |
|
3-way water valve for PS-DC/DCE fan coil units, for 2 pipe units it is used for heating and cooling, for 4 pipe units it is used only for cooling, 1" connection |
|
VAL.10.DIN.DC |
Balancing water valve for PS-DC/DCE fan coil units, for 2 pipe units it is used for heating and cooling, for 4 pipe units it is used only for cooling, 1" connection |
|
VAL.10.DIN.DC |
|
Balancing water valve for PS-DC/DCE fan coil units, for 2 pipe units it is used for heating and cooling, for 4 pipe units it is used only for cooling, 1" connection |
|
POM.CON.20.DC |
Condensate drain pump for PS-DC/DCE fan coil units, flow rate 20 l/h |
|
POM.CON.20.DC |
|
Condensate drain pump for PS-DC/DCE fan coil units, flow rate 20 l/h |
|
PLE.CIR.220 |
Air inlet / outlet spigot plenum for 220 / 224 size PS-DC/DCE fan coils, quantity of spigots 3 pcs., diameter of spigots Ø150 mm |
|
PLE.CIR.220 |
|
Air inlet / outlet spigot plenum for 220 / 224 size PS-DC/DCE fan coils, quantity of spigots 3 pcs., diameter of spigots Ø150 mm |
|
TLDCT.220 |
Air inlet / outlet adjustable length telescopic plenum for 220 / 224 size PS-DC/DCE fan coil units, dimensions 200x1290 mm |
|
TLDCT.220 |
|
Air inlet / outlet adjustable length telescopic plenum for 220 / 224 size PS-DC/DCE fan coil units, dimensions 200x1290 mm |
|
GRM.220 |
Aluminium air supply grille with adjustable fins for 220 / 224 size PS-DC/DCE fan coil units, dimensions 200x1290 mm |
|
GRM.220 |
|
Aluminium air supply grille with adjustable fins for 220 / 224 size PS-DC/DCE fan coil units, dimensions 200x1290 mm |
|
GRA.220 |
Aluminium air intake grille for 220 / 224 size PS-DC/DCE fan coil units, dimensions 200x1290 mm |
|
GRA.220 |
|
Aluminium air intake grille for 220 / 224 size PS-DC/DCE fan coil units, dimensions 200x1290 mm |
|
GRF.220 |
Aluminium air intake grille with G3 class filter for 220 / 224 size PS-DC/DCE fan coil units, dimensions 400x1000 mm |
|
GRF.220 |
|
Aluminium air intake grille with G3 class filter for 220 / 224 size PS-DC/DCE fan coil units, dimensions 400x1000 mm |
|
LAM.UV.LED.220 |
Antibacterial UV-C LED lamp for 220 / 224 size PS-DC/DCE fan coil units |
|
LAM.UV.LED.220 |
|
Antibacterial UV-C LED lamp for 220 / 224 size PS-DC/DCE fan coil units |
|
GRM-V-DC |
Painting of GRM DC air supply grille in selectable RAL color |
|
GRM-V-DC |
|
Painting of GRM DC air supply grille in selectable RAL color |
|
GRA-V-DC |
Painting of GRA DC air intake grille in selectable RAL color |
|
GRA-V-DC |
|
Painting of GRA DC air intake grille in selectable RAL color |
|
GRF-V-DC |
Painting of GRF HDC air intake grille in selectable RAL color |
|
GRF-V-DC |
|
Painting of GRF HDC air intake grille in selectable RAL color |