Gas absorption heat pump, takes heat from Air and gives it to Water for heating or domestic hot water production, connected with additional condensing boiler, maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
GITIE-AHAY - takes heat from Air and gives it to Water for heating or domestic hot water production, connected with additional condensing boiler
GITIE AHAY35/2 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -25°C, 2-pipe hydraulic connection
GITIE AHAY35/2 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -25°C, 2-pipe hydraulic connection
GITIE AHAY35/4 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY35/4 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power absorption 1.19 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 477 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY35/2 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 2-pipe hydraulic connection
GITIE AHAY35/2 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 2-pipe hydraulic connection
GITIE AHAY35/4 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY35/4 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 77.7 kW (A7/W35), total gas utilization efficiency GUE 131% (A7/W35), condensing boiler heat output 33.4 kW (80/60°C), condensing boiler efficiency 106.4% (50/30°C), A++ energy class ErP on 55°C operation, gas (G20) consumption 6.32 m³/h, electrical power consumption while fan working on min/max speed 0.85/1.12 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 487 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -30°C, 4-pipe hydraulic connection
GITIE AHAY50/2 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/2 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/4 STANDARD Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE AHAY50/4 STANDARD
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power absorption 1.22 kW, sound pressure level (at 5 m distance) 57.6 dB(A), electrical degree of protection IP X5D, weight 490 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE AHAY50/2 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/2 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 2-pipe hydraulic connection
GITIE AHAY50/4 LOW-NOISE Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE AHAY50/4 LOW-NOISE
Maximum outlet water temperature for heating/DHW 65/80°C, total heat output 94.8 kW (A7/W35), total gas utilization efficiency GUE 126% (A7/W35), condensing boiler heat output 49.2 kW (80/60°C), condensing boiler efficiency 106.8% (50/30°C), gas (G20) consumption 8.01 m³/h, electrical power consumption while fan working on min/max speed 0.88/1.15 kW, sound pressure level while fan working on min/max speed (at 5 m distance) 49.0/52.0 dB(A), electrical degree of protection IP X5D, weight 500 kg, outside working temperature -15°C/+40°C, can be ordered with special winter kit for operation on lower temperature down to -?°C, 4-pipe hydraulic connection
GITIE-AHAY gas absorption heat pump Air/Water with additional condensing boiler
Manuals 13 MB
Atbilstības deklarācijas 2.9 MB
Katalogi 3.5 MB
DDC control panel
Manuals 12.4 MB
Bukleti 795 KB
MODBUS protocol for connection to BMS 690 KB
RB100 (Robur Box 100) control interface
Manuals 3.1 MB
Modelis: GITIE AHAY35/4 LOW-NOISE
Additional accessories for GAHP gas absorption heat pumps and AY boilers
OCRM009 Control panel DDC for configuring AY boilers, RTY links of those boilers, gas heat pumps
OCRM009
Control panel DDC for configuring AY boilers, RTY links of those boilers, gas heat pumps
ODSP014 RB100 (Robur Box 100) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: heating, DHW and cooling mode management; 3-way valve management for switching heating and DHW; control and error alarm.
ODSP014
RB100 (Robur Box 100) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: heating, DHW and cooling mode management; 3-way valve management for switching heating and DHW; control and error alarm.
ODSP023 RB200 (Robur Box 200) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: integration of third parties appliances, i.e. in case of retrofitting of existing systems; control of water circulation of primary and secondary circuits; 3-way valve management for switching heating and DHW; control and error alarm.
ODSP023
RB200 (Robur Box 200) control system for Robur gas absorption heat pumps fitted with Direct Digital Control (DDC). Main functions: integration of third parties appliances, i.e. in case of retrofitting of existing systems; control of water circulation of primary and secondary circuits; 3-way valve management for switching heating and DHW; control and error alarm.
OSND007 Outdoor air temperature probe for DDC control panel
OSND007
Outdoor air temperature probe for DDC control panel
ODSP033 Roburberry microcomputer for remote monitoring and control of devices, connects to the DDC control panel via RS485 port
ODSP033
Roburberry microcomputer for remote monitoring and control of devices, connects to the DDC control panel via RS485 port
ODSP052 GSM modem for Roburberry microcomputer
ODSP052
GSM modem for Roburberry microcomputer
RBCLOUD2Y 2-year free connection of the Roburberry microcomputer to the Robur Cloud remote device monitoring and control system
RBCLOUD2Y
2-year free connection of the Roburberry microcomputer to the Robur Cloud remote device monitoring and control system