Fan coil, for wall mounting or standing on the floor, bottom air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection, 2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
PS-FL 2T - for wall mounting or standing on the floor, bottom air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FL 2T 030 2.32/2.47/3.14 kW heating capacity or 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FL 2T 030
2.32/2.47/3.14 kW heating capacity or 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FL 2T 050 2.76/3.54/4.43 kW heating capacity or 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FL 2T 050
2.76/3.54/4.43 kW heating capacity or 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FL 2T 070 4.35/4.71/6.08 kW heating capacity or 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FL 2T 070
4.35/4.71/6.08 kW heating capacity or 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FL 2T 100 4.82/6.66/8.58 kW heating capacity or 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FL 2T 100
4.82/6.66/8.58 kW heating capacity or 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FL 4T - for wall mounting or standing on the floor, bottom air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FL 4T 034 2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FL 4T 034
2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FL 4T 054 3.06/3.75/4.46 kW heating capacity in 1 row heat exchanger and 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FL 4T 054
3.06/3.75/4.46 kW heating capacity in 1 row heat exchanger and 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FL 4T 074 4.64/4.95/6.00 kW heating capacity in 1 row heat exchanger and 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FL 4T 074
4.64/4.95/6.00 kW heating capacity in 1 row heat exchanger and 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FL 4T 104 5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FL 4T 104
5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLF 2T - for wall mounting or standing on the floor, front air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLF 2T 030 2.32/2.47/3.14 kW heating capacity or 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLF 2T 030
2.32/2.47/3.14 kW heating capacity or 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLF 2T 050 2.76/3.54/4.43 kW heating capacity or 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLF 2T 050
2.76/3.54/4.43 kW heating capacity or 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLF 2T 070 4.35/4.71/6.08 kW heating capacity or 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLF 2T 070
4.35/4.71/6.08 kW heating capacity or 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLF 2T 100 4.82/6.66/8.58 kW heating capacity or 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLF 2T 100
4.82/6.66/8.58 kW heating capacity or 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLF 4T - for wall mounting or standing on the floor, front air intake, three-speed AC type centrifugal fan, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLF 4T 034 2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLF 4T 034
2.43/2.54/3.07 kW heating capacity in 1 row heat exchanger and 1.89/2.00/2.46 kW cooling capacity in 3 row heat exchanger, air flow 260/280/370 m³/h, sound pressure level 32/34/40 dB(A), max. fan power 61 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLF 4T 054 3.06/3.75/4.46 kW heating capacity in 1 row heat exchanger and 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLF 4T 054
3.06/3.75/4.46 kW heating capacity in 1 row heat exchanger and 2.43/3.04/3.78 kW cooling capacity in 3 row heat exchanger, air flow 295/390/505 m³/h, sound pressure level 32/38/44 dB(A), max. fan power 74 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLF 4T 074 4.64/4.95/6.00 kW heating capacity in 1 row heat exchanger and 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLF 4T 074
4.64/4.95/6.00 kW heating capacity in 1 row heat exchanger and 3.88/4.19/5.32 kW cooling capacity in 3 row heat exchanger, air flow 470/515/690 m³/h, sound pressure level 33/34/42 dB(A), max. fan power 138 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLF 4T 104 5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLF 4T 104
5.48/7.01/8.52 kW heating capacity in 1 row heat exchanger and 4.31/5.83/7.40 kW cooling capacity in 3 row heat exchanger, air flow 515/740/995 m³/h, sound pressure level 33/41/47 dB(A), max. fan power 186 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLE 2T - for wall mounting or standing on the floor, bottom air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLE 2T 030 1.36/2.44/3.26 kW heating capacity or 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLE 2T 030
1.36/2.44/3.26 kW heating capacity or 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLE 2T 050 1.65/3.08/4.03 kW heating capacity or 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLE 2T 050
1.65/3.08/4.03 kW heating capacity or 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLE 2T 070 1.94/4.33/5.64 kW heating capacity or 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLE 2T 070
1.94/4.33/5.64 kW heating capacity or 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLE 2T 100 2.22/5.02/6.68 kW heating capacity or 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLE 2T 100
2.22/5.02/6.68 kW heating capacity or 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLE 4T - for wall mounting or standing on the floor, bottom air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLE 4T 034 1.24/2.03/2.50 kW heating capacity in 1 row heat exchanger and 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLE 4T 034
1.24/2.03/2.50 kW heating capacity in 1 row heat exchanger and 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLE 4T 054 1.60/2.61/3.24 kW heating capacity in 1 row heat exchanger and 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLE 4T 054
1.60/2.61/3.24 kW heating capacity in 1 row heat exchanger and 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLE 4T 074 1.95/3.67/4.54 kW heating capacity in 1 row heat exchanger and 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLE 4T 074
1.95/3.67/4.54 kW heating capacity in 1 row heat exchanger and 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLE 4T 104 2.23/4.22/5.32 kW heating capacity in 1 row heat exchanger and 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLE 4T 104
2.23/4.22/5.32 kW heating capacity in 1 row heat exchanger and 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEF 2T - for wall mounting or standing on the floor, front air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 50°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 2 pipe connection
PS-FLEF 2T 030 1.36/2.44/3.26 kW heating capacity or 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEF 2T 030
1.36/2.44/3.26 kW heating capacity or 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEF 2T 050 1.65/3.08/4.03 kW heating capacity or 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEF 2T 050
1.65/3.08/4.03 kW heating capacity or 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEF 2T 070 1.94/4.33/5.64 kW heating capacity or 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEF 2T 070
1.94/4.33/5.64 kW heating capacity or 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEF 2T 100 2.22/5.02/6.68 kW heating capacity or 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEF 2T 100
2.22/5.02/6.68 kW heating capacity or 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEF 4T - for wall mounting or standing on the floor, front air intake, EC type centrifugal fan, data is provided for the fan operating at three speeds at 2/6/10 V, galvanized steel frame with anti-condensation coating and sound-absorbing material, galvanized steel casing painted in RAL9010 white color, delivered with condensate drain pan, G2 class air filter, heating capacity is calculated at 70/60°C water and 20°C air temperature, cooling capacity at 7/12°C water and 27°C air temperature, 4 pipe connection
PS-FLEF 4T 034 1.24/2.03/2.50 kW heating capacity in 1 row heat exchanger and 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEF 4T 034
1.24/2.03/2.50 kW heating capacity in 1 row heat exchanger and 0.98/1.44/2.18 kW cooling capacity in 3 row heat exchanger, air flow 170/360/495 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 43 W, dimensions 840x220xH485 mm, weight 24.5 kg, 2 year WARRANTY
PS-FLEF 4T 054 1.60/2.61/3.24 kW heating capacity in 1 row heat exchanger and 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEF 4T 054
1.60/2.61/3.24 kW heating capacity in 1 row heat exchanger and 1.24/2.35/3.11 kW cooling capacity in 3 row heat exchanger, air flow 190/390/540 m³/h, sound pressure level 33/41/48 dB(A), max. fan power 44 W, dimensions 1040x220xH485 mm, weight 28.5 kg, 2 year WARRANTY
PS-FLEF 4T 074 1.95/3.67/4.54 kW heating capacity in 1 row heat exchanger and 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEF 4T 074
1.95/3.67/4.54 kW heating capacity in 1 row heat exchanger and 1.59/3.53/4.57 kW cooling capacity in 3 row heat exchanger, air flow 215/540/745 m³/h, sound pressure level 33/39/46 dB(A), max. fan power 49 W, dimensions 1240x220xH485 mm, weight 33.5 kg, 2 year WARRANTY
PS-FLEF 4T 104 2.23/4.22/5.32 kW heating capacity in 1 row heat exchanger and 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FLEF 4T 104
2.23/4.22/5.32 kW heating capacity in 1 row heat exchanger and 1.77/4.05/5.36 kW cooling capacity in 3 row heat exchanger, air flow 245/620/875 m³/h, sound pressure level 33/39/48 dB(A), max. fan power 55 W, dimensions 1440x220xH485 mm, weight 39.5 kg, 2 year WARRANTY
PS-FL / PS-FLE / PS-FLF / PS-FLEF / PS-FLH / PS-FLEH standard fan coil units
Manuals 356 KB
Bukleti 1.2 MB
Katalogi 527 KB
Fan coils controllers
Bukleti 8.1 MB
Modelis: PS-FL 4T 034
Control panels for fan coils
TER.ANA Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.ANA
Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.ANA.M Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for installation inside device, for use with PS-FL/FLF units
TER.ANA.M
Suitable for 2-pipe and 4-pipe units with AC fans, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for installation inside device, for use with PS-FL/FLF units
TER.ANA.S Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units without valves
TER.ANA.S
Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units without valves
TER.ANA.S.M Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor , for installation inside device, for use with PS-FL/FLF units without valves
TER.ANA.S.M
Suitable for 2-pipe and 4-pipe units with AC fans, automatic 3 steps fan speed selection, integrated thermostat, possibility to remotely turn device on/off, possibility to connect remote air sensor , for installation inside device, for use with PS-FL/FLF units without valves
TER.DIG Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG.M Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for installation inside device, for use with PS-FL/FLF units
TER.DIG.M
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual 3 steps fan speed selection, integrated thermostat, manual summer/winter mode, on/off valves control, possibility to connect remote air sensor , for installation inside device, for use with PS-FL/FLF units
TER.DIG.S Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, possibility to remotely turn device on/off, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.DIG.S
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, possibility to remotely turn device on/off, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via Modbus RTU protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BUS.M Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via Modbus RTU protocol, for installation inside device, for use with PS-FL/FLF units
TER.BUS.M
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via Modbus RTU protocol, for installation inside device, for use with PS-FL/FLF units
TER.BAC Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BAC
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via BACnet MS/TP protocol, for use with PS-FS, PS-FL/FLF/FLH, PS-CL/CLH, PS-UWL/UWLF/UWLV, PS-DC/HDC units
TER.BAC.M Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via BACnet MS/TP protocol, for installation inside device, for use with PS-FL/FLF units
TER.BAC.M
Suitable for 2-pipe and 4-pipe units with AC fans, LCD display, manual and automatic 3 steps fan speed selection, integrated thermostat, automatic summer/winter mode if used with optional sensor, programmable weekly calendar, possibility to remotely turn device on/off, possibility to control additional electric heater, on/off valves control, 0-10V modulating valves control, possibility to connect remote air sensor , RS485 connection to BMS via BACnet MS/TP protocol, for installation inside device, for use with PS-FL/FLF units
Accessories for fan coils controls
KIT.WI-FI Electronic board for PS-FS, PS-FL/FLF/FLH, PS-UWL/UWLF/UWLV, PS-DC/HDC fan coil units with AC type fan control via Wi-Fi, delivered with air temperature probe
KIT.WI-FI
Electronic board for PS-FS, PS-FL/FLF/FLH, PS-UWL/UWLF/UWLV, PS-DC/HDC fan coil units with AC type fan control via Wi-Fi, delivered with air temperature probe
IDP Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans
IDP
Power interface distributor that allows to use single TER.ANA / TER.ANA.M / TER.ANA.S / TER.ANA.S.M / TER.DIG / TER.DIG.M / TER.DIG.D / TER.DIG.D.M / TER.DIG.S / TER.TOUCH / TER.TOUCH.M control panel for up to 4 fan coil units with AC type fans
Water valves
ATT.230 On/Off actuator for water valve, powered by 230 V
ATT.230
On/Off actuator for water valve, powered by 230 V
ATT.24 On/Off actuator for water valve, powered by 24 V
ATT.24
On/Off actuator for water valve, powered by 24 V
ATT.MOD Modulating by 0-10 V signal actuator for water valve
ATT.MOD
Modulating by 0-10 V signal actuator for water valve
VAL.2V.12.FL 2-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.2V.12.FL
2-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.3V.12.FL 3-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.3V.12.FL
3-way water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.12.DIN.FL Balancing water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
VAL.12.DIN.FL
Balancing water valve for PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units, 1/2" connection
Condensate drain pumps
POM.CON.20 Condensate drain pump for PS-WLE, PS-FL/FLF/FLH/FLE/FLEF/FLEH, PS-UWLED, PS-DC/DCE/HDC/HDCE fan coil units, flow rate 20 l/h
POM.CON.20
Condensate drain pump for PS-WLE, PS-FL/FLF/FLH/FLE/FLEF/FLEH, PS-UWLED, PS-DC/DCE/HDC/HDCE fan coil units, flow rate 20 l/h
Support feet
SUPP.FL Support feet for standing on the floor PS-FL/FLE fan coil units, 10 cm height
SUPP.FL
Support feet for standing on the floor PS-FL/FLE fan coil units, 10 cm height
Painting in non-standard colors
FL030.RAL Painting of casing in non-standard RAL color for 030 - 054 size PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units
FL030.RAL
Painting of casing in non-standard RAL color for 030 - 054 size PS-FL/FLF/FLH/FLE/FLEF/FLEH fan coil units