Ventilācijas gaisa pievades un aizvades režģis, ko pievieno pie spirālveida gaisvadiem. Priekšējā ietvara forma saskan ar gaisvada diametru. Izmantojami zema un vidēja spiediena sistēmās. Ieteicams uzstādīt gaisvados un ventilācijas atverēs, izmantojot redzamas skrūves, ko ievieto priekšējā ietvarā ...
Vai jūs interesē šis produkts? Sazinieties ar mums:

Roberts Priekulis

LV, RU, EN
+371 286 22395

Tirdzniecības pārstāvis Latvijā Saņemt piedāvājumu
Attention! We do not stock SAW-POL ventilation components, all products from this supplier are custom made and delivered to the customer directly from the manufacturer's warehouse. We are sorry but for this reason we can not accept orders for individual goods, we only accept orders for the high quantity of SAW-POL products.
Noklikšķiniet uz modeļa: parādīsies tehniskā informācija, izmēri, piederumi
STS-S/GU - bended frame for installation in spiral ducts, vertically placed and manually adjustable each grille blade with cantilevered damper behind them, manufactured from powder coated steel, RAL9006 color, visible assembly through screws in holes in grille front frame
STS-S/GU/125x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 125x75 mm, air flow opening dimensions 110x60 mm, effective area ? m²
STS-S/GU/125x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 125x75 mm, air flow opening dimensions 110x60 mm, effective area ? m²
STS-S/GU/225x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 225x75 mm, air flow opening dimensions 210x60 mm, effective area 0.012 m²
STS-S/GU/225x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 225x75 mm, air flow opening dimensions 210x60 mm, effective area 0.012 m²
STS-S/GU/325x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 325x75 mm, air flow opening dimensions 310x60 mm, effective area 0.017 m²
STS-S/GU/325x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 325x75 mm, air flow opening dimensions 310x60 mm, effective area 0.017 m²
STS-S/GU/425x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 425x75 mm, air flow opening dimensions 410x60 mm, effective area 0.022 m²
STS-S/GU/425x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 425x75 mm, air flow opening dimensions 410x60 mm, effective area 0.022 m²
STS-S/GU/525x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 525x75 mm, air flow opening dimensions 510x60 mm, effective area 0.025 m²
STS-S/GU/525x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 525x75 mm, air flow opening dimensions 510x60 mm, effective area 0.025 m²
STS-S/GU/625x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 625x75 mm, air flow opening dimensions 610x60 mm, effective area 0.030 m²
STS-S/GU/625x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 625x75 mm, air flow opening dimensions 610x60 mm, effective area 0.030 m²
STS-S/GU/825x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 825x75 mm, air flow opening dimensions 810x60 mm, effective area 0.039 m²
STS-S/GU/825x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 825x75 mm, air flow opening dimensions 810x60 mm, effective area 0.039 m²
STS-S/GU/1025x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 1025x75 mm, air flow opening dimensions 1010x60 mm, effective area 0.048 m²
STS-S/GU/1025x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 1025x75 mm, air flow opening dimensions 1010x60 mm, effective area 0.048 m²
STS-S/GU/1225x75/200 Spiral duct diameter Ø200 mm, installation hole on duct dimensions 1225x75 mm, air flow opening dimensions 1210x60 mm, effective area 0.057 m²
STS-S/GU/1225x75/200
Spiral duct diameter Ø200 mm, installation hole on duct dimensions 1225x75 mm, air flow opening dimensions 1210x60 mm, effective area 0.057 m²
STS-S/GU/125x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 125x125 mm, air flow opening dimensions 110x110 mm, effective area 0.012 m²
STS-S/GU/125x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 125x125 mm, air flow opening dimensions 110x110 mm, effective area 0.012 m²
STS-S/GU/225x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 225x125 mm, air flow opening dimensions 210x110 mm, effective area 0.020 m²
STS-S/GU/225x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 225x125 mm, air flow opening dimensions 210x110 mm, effective area 0.020 m²
STS-S/GU/325x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 325x125 mm, air flow opening dimensions 310x110 mm, effective area 0.029 m²
STS-S/GU/325x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 325x125 mm, air flow opening dimensions 310x110 mm, effective area 0.029 m²
STS-S/GU/425x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 425x125 mm, air flow opening dimensions 410x110 mm, effective area 0.037 m²
STS-S/GU/425x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 425x125 mm, air flow opening dimensions 410x110 mm, effective area 0.037 m²
STS-S/GU/525x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 525x125 mm, air flow opening dimensions 510x110 mm, effective area 0.043 m²
STS-S/GU/525x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 525x125 mm, air flow opening dimensions 510x110 mm, effective area 0.043 m²
STS-S/GU/625x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 625x125 mm, air flow opening dimensions 610x110 mm, effective area 0.051 m²
STS-S/GU/625x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 625x125 mm, air flow opening dimensions 610x110 mm, effective area 0.051 m²
STS-S/GU/825x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 825x125 mm, air flow opening dimensions 810x110 mm, effective area 0.068 m²
STS-S/GU/825x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 825x125 mm, air flow opening dimensions 810x110 mm, effective area 0.068 m²
STS-S/GU/1025x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 1025x125 mm, air flow opening dimensions 1010x110 mm, effective area 0.085 m²
STS-S/GU/1025x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 1025x125 mm, air flow opening dimensions 1010x110 mm, effective area 0.085 m²
STS-S/GU/1225x125/250 Spiral duct diameter Ø250 mm, installation hole on duct dimensions 1225x125 mm, air flow opening dimensions 1210x110 mm, effective area 0.101 m²
STS-S/GU/1225x125/250
Spiral duct diameter Ø250 mm, installation hole on duct dimensions 1225x125 mm, air flow opening dimensions 1210x110 mm, effective area 0.101 m²
STS-S/GU/225x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 225x225 mm, air flow opening dimensions 210x210 mm, effective area 0.036 m²
STS-S/GU/225x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 225x225 mm, air flow opening dimensions 210x210 mm, effective area 0.036 m²
STS-S/GU/325x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 325x225 mm, air flow opening dimensions 310x210 mm, effective area 0.051 m²
STS-S/GU/325x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 325x225 mm, air flow opening dimensions 310x210 mm, effective area 0.051 m²
STS-S/GU/425x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 425x225 mm, air flow opening dimensions 410x210 mm, effective area 0.067 m²
STS-S/GU/425x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 425x225 mm, air flow opening dimensions 410x210 mm, effective area 0.067 m²
STS-S/GU/525x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 525x225 mm, air flow opening dimensions 510x210 mm, effective area 0.078 m²
STS-S/GU/525x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 525x225 mm, air flow opening dimensions 510x210 mm, effective area 0.078 m²
STS-S/GU/625x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 625x225 mm, air flow opening dimensions 610x210 mm, effective area 0.094 m²
STS-S/GU/625x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 625x225 mm, air flow opening dimensions 610x210 mm, effective area 0.094 m²
STS-S/GU/825x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 825x225 mm, air flow opening dimensions 810x210 mm, effective area 0.126 m²
STS-S/GU/825x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 825x225 mm, air flow opening dimensions 810x210 mm, effective area 0.126 m²
STS-S/GU/1025x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 1025x225 mm, air flow opening dimensions 1010x210 mm, effective area 0.158 m²
STS-S/GU/1025x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 1025x225 mm, air flow opening dimensions 1010x210 mm, effective area 0.158 m²
STS-S/GU/1225x225/350 Spiral duct diameter Ø350 mm, installation hole on duct dimensions 1225x225 mm, air flow opening dimensions 1210x210 mm, effective area 0.190 m²
STS-S/GU/1225x225/350
Spiral duct diameter Ø350 mm, installation hole on duct dimensions 1225x225 mm, air flow opening dimensions 1210x210 mm, effective area 0.190 m²
STS-S/GU/325x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 325x325 mm, air flow opening dimensions 310x310 mm, effective area 0.074 m²
STS-S/GU/325x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 325x325 mm, air flow opening dimensions 310x310 mm, effective area 0.074 m²
STS-S/GU/425x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 425x325 mm, air flow opening dimensions 410x310 mm, effective area 0.098 m²
STS-S/GU/425x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 425x325 mm, air flow opening dimensions 410x310 mm, effective area 0.098 m²
STS-S/GU/525x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 525x325 mm, air flow opening dimensions 510x310 mm, effective area 0.114 m²
STS-S/GU/525x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 525x325 mm, air flow opening dimensions 510x310 mm, effective area 0.114 m²
STS-S/GU/625x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 625x325 mm, air flow opening dimensions 610x310 mm, effective area 0.137 m²
STS-S/GU/625x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 625x325 mm, air flow opening dimensions 610x310 mm, effective area 0.137 m²
STS-S/GU/825x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 825x325 mm, air flow opening dimensions 810x310 mm, effective area 0.184 m²
STS-S/GU/825x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 825x325 mm, air flow opening dimensions 810x310 mm, effective area 0.184 m²
STS-S/GU/1025x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 1025x325 mm, air flow opening dimensions 1010x310 mm, effective area 0.231 m²
STS-S/GU/1025x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 1025x325 mm, air flow opening dimensions 1010x310 mm, effective area 0.231 m²
STS-S/GU/1225x325/500 Spiral duct diameter Ø500 mm, installation hole on duct dimensions 1225x325 mm, air flow opening dimensions 1210x310 mm, effective area 0.282 m²
STS-S/GU/1225x325/500
Spiral duct diameter Ø500 mm, installation hole on duct dimensions 1225x325 mm, air flow opening dimensions 1210x310 mm, effective area 0.282 m²
STS-S/GU/425x425/630 Spiral duct diameter Ø630 mm, installation hole on duct dimensions 425x425 mm, air flow opening dimensions 410x410 mm, effective area 0.132 m²
STS-S/GU/425x425/630
Spiral duct diameter Ø630 mm, installation hole on duct dimensions 425x425 mm, air flow opening dimensions 410x410 mm, effective area 0.132 m²
STS-S/GU/525x425/630 Spiral duct diameter Ø630 mm, installation hole on duct dimensions 525x425 mm, air flow opening dimensions 510x410 mm, effective area 0.150 m²
STS-S/GU/525x425/630
Spiral duct diameter Ø630 mm, installation hole on duct dimensions 525x425 mm, air flow opening dimensions 510x410 mm, effective area 0.150 m²
STS-S/GU/625x425/630 Spiral duct diameter Ø630 mm, installation hole on duct dimensions 625x425 mm, air flow opening dimensions 610x410 mm, effective area 0.181 m²
STS-S/GU/625x425/630
Spiral duct diameter Ø630 mm, installation hole on duct dimensions 625x425 mm, air flow opening dimensions 610x410 mm, effective area 0.181 m²
STS-S/GU/825x425/630 Spiral duct diameter Ø630 mm, installation hole on duct dimensions 825x425 mm, air flow opening dimensions 810x410 mm, effective area 0.242 m²
STS-S/GU/825x425/630
Spiral duct diameter Ø630 mm, installation hole on duct dimensions 825x425 mm, air flow opening dimensions 810x410 mm, effective area 0.242 m²
STS-S/GU/1025x425/630 Spiral duct diameter Ø630 mm, installation hole on duct dimensions 1025x425 mm, air flow opening dimensions 1010x410 mm, effective area 0.304 m²
STS-S/GU/1025x425/630
Spiral duct diameter Ø630 mm, installation hole on duct dimensions 1025x425 mm, air flow opening dimensions 1010x410 mm, effective area 0.304 m²
STS-S/GU/1225x425/630 Spiral duct diameter Ø630 mm, installation hole on duct dimensions 1225x425 mm, air flow opening dimensions 1210x410 mm, effective area 0.366 m²
STS-S/GU/1225x425/630
Spiral duct diameter Ø630 mm, installation hole on duct dimensions 1225x425 mm, air flow opening dimensions 1210x410 mm, effective area 0.366 m²
STS-S/GU/525x525/800 Spiral duct diameter Ø800 mm, installation hole on duct dimensions 525x525 mm, air flow opening dimensions 510x510 mm, effective area 0.185 m²
STS-S/GU/525x525/800
Spiral duct diameter Ø800 mm, installation hole on duct dimensions 525x525 mm, air flow opening dimensions 510x510 mm, effective area 0.185 m²
STS-S/GU/625x525/800 Spiral duct diameter Ø800 mm, installation hole on duct dimensions 625x525 mm, air flow opening dimensions 610x510 mm, effective area 0.224 m²
STS-S/GU/625x525/800
Spiral duct diameter Ø800 mm, installation hole on duct dimensions 625x525 mm, air flow opening dimensions 610x510 mm, effective area 0.224 m²
STS-S/GU/825x525/800 Spiral duct diameter Ø800 mm, installation hole on duct dimensions 825x525 mm, air flow opening dimensions 810x510 mm, effective area 0.230 m²
STS-S/GU/825x525/800
Spiral duct diameter Ø800 mm, installation hole on duct dimensions 825x525 mm, air flow opening dimensions 810x510 mm, effective area 0.230 m²
STS-S/GU/1025x525/800 Spiral duct diameter Ø800 mm, installation hole on duct dimensions 1025x525 mm, air flow opening dimensions 1010x510 mm, effective area 0.377 m²
STS-S/GU/1025x525/800
Spiral duct diameter Ø800 mm, installation hole on duct dimensions 1025x525 mm, air flow opening dimensions 1010x510 mm, effective area 0.377 m²
STS-S/GU/1225x525/800 Spiral duct diameter Ø800 mm, installation hole on duct dimensions 1225x525 mm, air flow opening dimensions 1210x510 mm, effective area 0.454 m²
STS-S/GU/1225x525/800
Spiral duct diameter Ø800 mm, installation hole on duct dimensions 1225x525 mm, air flow opening dimensions 1210x510 mm, effective area 0.454 m²
STS-S/GU/625x625/1000 Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 625x625 mm, air flow opening dimensions 610x610 mm, effective area 0.267 m²
STS-S/GU/625x625/1000
Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 625x625 mm, air flow opening dimensions 610x610 mm, effective area 0.267 m²
STS-S/GU/825x625/1000 Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 825x625 mm, air flow opening dimensions 810x610 mm, effective area 0.359 m²
STS-S/GU/825x625/1000
Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 825x625 mm, air flow opening dimensions 810x610 mm, effective area 0.359 m²
STS-S/GU/1025x625/1000 Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 1025x625 mm, air flow opening dimensions 1010x610 mm, effective area 0.450 m²
STS-S/GU/1025x625/1000
Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 1025x625 mm, air flow opening dimensions 1010x610 mm, effective area 0.450 m²
STS-S/GU/1225x625/1000 Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 1225x625 mm, air flow opening dimensions 1210x610 mm, effective area 0.542 m²
STS-S/GU/1225x625/1000
Spiral duct diameter Ø1000 mm, installation hole on duct dimensions 1225x625 mm, air flow opening dimensions 1210x610 mm, effective area 0.542 m²

Ventilācijas gaisa pievades un aizvades režģis, ko pievieno pie spirālveida gaisvadiem. Priekšējā ietvara forma saskan ar gaisvada diametru. Izmantojami zema un vidēja spiediena sistēmās. Ieteicams uzstādīt gaisvados un ventilācijas atverēs, izmantojot redzamas skrūves, ko ievieto priekšējā ietvarā izveidotajos caurumos. Priekšējais ietvars ir izgatavots no tērauda profilelementiem. Latu novietojums ir vertikāls (STS-S). Latu nolieces leņķi var regulēt, manuāli ieregulējot katru latu atsevišķi. STS-S/G ir aprīkots ar aizvaru (standartvariantā – konsoles aizvars).

Šiem režģiem ir higiēnas sertifikāts HK/K/0522/02/2016.

Izmantotie materiāli, uzbūve

Materiāli:
- galvanizēts tērauds ar pulvertehnikā veidotu pārklājumu RAL 9016. numura baltā krāsā (standartvariants);
- alumīnijs;
- nerūsīgs tērauds (tips 1,4301 vai 1,4404).
Pēc pasūtījuma var nokrāsot ar pulvermetodi jebkurā RAL paletes krāsā.

STS-S/G spirālveida gaisvadiem pievienojams režģis ar regulējamām latām un konsoles aizvaru
Atbilstības deklarācijas 245 KB
Katalogi 2.4 MB
Hygienic certificate 1.1 MB